Investigation of construction influence of half mask design on their ergonomic properties
Cheberiachko S.I1 , Yavorska O.O1 , Cheberiachko Yu.I1
1National Mining University, Dnipropetrovsk, Ukraine
Min. miner. depos. 2014, 8(4):437-445
https://doi.org/10.15407/mining08.04.437
Full text (PDF)
      ABSTRACT
      In t article research results of ergonomic properties of different design filtering half masks is published. The results of assessing the influence of air moisture on breathing resistance of personal respiratory protection are shown.
      REFERENCES
Effect on breathing resistance of a surgical mask worn over a N95 filtering facepiece respirator / M.R. Vojtko, M.R. Roberge, R.J. Vojtko [etc.] // Journal of the International Society f or Respiratory Protection, 2008. – No 25. – P. 1 – 8.
Inspiratory Flow Rates During Hard Work When Breathing Through Different Respirator Inhalation and Exhalation Resistances / K. Coyne, D. Caretti, W. Scott [etc.] // Journal of Occupational and Environmental Hygiene – 2006. – No 3(9). – P. 490 – 500.
https://doi.org/10.1080/15459620600867807
Cheberyachko S.I. Issledovanie soprotivleniya vozdushnomu potoku fil'truyushchikh materialov s polipropilenovykh volokon / S.I. Cheberyachko // Visnik Zhitomirs'kogo inzh.-tekhn. in-tu. – 2002. – No 18. – S. 183 – 185.
Effects of wearing N95 and surgical facemasks on heart rate, thermal stress and subjective sensations / Y. Li, H. Tokura, Y.P. Guo [etc.] // International Archives of Occupational and Environmental Health. – 2005. – No 78. – P. 501 – 509.
https://doi.org/10.1007/s00420-004-0584-4
Cheberiachko S.I. Otsinka vplyvu zasobiv indyvidualnoho zakhystu orhaniv dykhannia na pratsezdatnist liudyny / S.I. Cheberiachko, Iu.I. Cheberiachko // Naukovyi visnyk NHU. – 2007. – No 7. – S. 64 – 66.
Monaghan W.M. Thermal imaging comparison of maximum surface temperatures achieved on N95 filtering facepiece respirators with and without exhalation valves at sedentary breathing volumes / W.M. Monaghan, M.R. Roberge, M. Rengasamy // Journal of Occupational and Environmental Hygiene. – 2009. – No 26. – P. 9 – 12.
Roberge R.J. Surgical mask placement over N95 filtering facepiece respirators: physiological effects on healthcare workers / R.J. Roberge, A. Coca, W.J. Williams [etc.] // Respirology. – 2010. – No 15. – P. 516 – 521.
https://doi.org/10.1111/j.1440-1843.2010.01713.x
Dhaniyala S. Theoretical modeling of filtration by nonuniform fibrous filters / S. Dhaniyala, Y. Benjamin, H. Liu // Journal of aerosol science and technology. – 2001. – No 34. – P. 170 – 178.
https://doi.org/10.1080/027868201300034763